OPTI-UPS International Corporation.
Contact Us
¡½ Product > UPS > Line Interactive UPS Series > Power Series

Line Interactive UPS Series
PS800B
PS1000B
PS1500B
PS2200B
PS3000B
PS1000B-RM
PS1500B-RM
PS2200B-RM
PS3000B-RM
PS500C
PS700C
PS1000C
PS1250C
PS1500C
PS2000C
PS3000C
Power Series -- PS800B
The PSB Series are the only line interactive pure sinewave UPS designed to meet everyone¡¦s needs. Our full line covers every possible application demand. There are five tower models, from PS800B to PS3000B, and four rack-mount models, from PS1000B-RM to PS3000B-RM.

Every PSB model utilizes digital line interactive technology that incorporates AVR.

AVR: (Automatic Voltage Regulator) Stabilizes all currents from over and under voltages, so that only the most clean and safe currents feed into your equipment.

Every single model is equipped with our full version of OPTI-SAFE Xtreme, UPS control software.

Sine wave: Represents energy entirely concentrated at a single frequency. The more concentrated the energy is the cleaner and safer the current will be. Fluctuations in energy called sags, brownouts and spikes, are harmful to machines and systems.

Features
* Pure sine wave
* LCD display panel
* Software controlled outlets to switch power on/off (PS1000~3000B)
* Higher efficiency
* 4 hours battery recharge time
* 1050 Joules surge energy rating
* Up to 8 battery backup outlets
* RS232 or USB (optional) connectivity
* Cold start from battery
* Smart power management software

Specifications

Model Name PS800B
Topology Line-interactive
On-battery Output Waveform Pure Sine Wave
INPUT
Maximum Capacity 800VA / 560W
Nominal Input Voltage 110/110/120Vac or 220/230/240Vac
Nominal Input Frequency 50Hz / 60Hz Auto Sensing
Input Voltage Range Rated Voltage +/-25%
Input Short Protection Circuit Breaker
OUTPUT
Nominal Output Voltage 100/110/115/120 Vac or 208/220/230/240Vac (selectable)
Output Voltage Regulation (DC Mode) Rated Voltage +/-5%
Transfer Time 4ms (typical)
Start on Battery Yes
Auto Restart Yes
Number of Outlets 6 Battery backup (US)
6 Battery backup (IEC)
PROTECTION
Automatic Voltage Regulation (AVR) Yes
Data Line Surge Protection RJ11 / RJ45
Surge Energy Rating

1050 Joules

BATTERY
User Replaceable Batteries 12V / 5AH¡Ñ2
Typical Backup Time (Full / Half load) 3 / 7min
Recharge Time to 90% < 4 Hours
ADVANCED WARNINGS / DIAGNOSTICS
Front Panel LEDs or LCD AC mode / Battery mode
Audible Alarms Battery mode / UPS fault / Overload
COMMUNICATIONS INTERFACE
Communication Port RS232*
ENVIRONMENTAL
Operation Temperature 0~40¢J / 32~104¢K
Storage Temperature -20~60¢J / -4~140¢K
Audible Noise (AC Mode) < 40dBA
PHYSICAL
Dimensions(Physical /Packing)
(L¡ÑW¡ÑH)

12.28¡Ñ5X7.68 / 15.35¡Ñ9.06¡Ñ11.81 (in)
312¡Ñ127¡Ñ195 / 390¡Ñ230¡Ñ300 (mm)

Weight (Net / Gross)

23.59 / 25.79 (lbs)
10.7 / 11.7 (kg)

CONFORMANCE
Approvals

UL / cUL; C-Tick, A-Tick; BSMI; CE; GOST-R

Specifications are subject to change without notice.
^ Battery unit is included with PS232 and PS3000B. Battery unit needs to be connected to Master unit before connecting any loads and turning on the UPS
# RS232 and USB model Provides both RS232 and USB connectivity, but only one connectivity can be used at a time. RS232 model provides only RS232 connectivity, but RS232 can be upgraded to USB connectivity through USP-Serial adapter.
* You can purchase RS232 to USB cable.
** Backup time depends on power consumption of equipment attached and on UPS battery capacity. Numbers here are for reference only.
¡@
Copyright ® 2008 OPTI-UPS International Corporation all rights reserved