| Model Name | PS2200B |
| Topology | Line-interactive |
| On-battery Output Waveform | Pure Sine Wave |
| INPUT | ¡@ |
| Maximum Capacity | 2200VA / 1760W |
| Nominal Input Voltage | 110/110/120Vac or 220/230/240Vac |
| Nominal Input Frequency | 50Hz / 60Hz Auto Sensing |
| Input Voltage Range | Rated Voltage +/-25% |
| Input Short Protection | Circuit Breaker |
| OUTPUT | ¡@ |
| Nominal Output Voltage | 100/110/115/120 Vac or 208/220/230/240Vac (selectable) |
| Output Voltage Regulation (DC Mode) | Rated Voltage +/-5% |
| Transfer Time | 4ms (typical) |
| Start on Battery | Yes |
| Auto Restart | Yes |
| Number of Outlets | 8 Battery backup (US) 8 Battery backup (IEC) |
| PROTECTION | ¡@ |
| Automatic Voltage Regulation (AVR) | Yes |
| Data Line Surge Protection | RJ11 / RJ45 |
| Surge Energy Rating | 1050 Joules |
| BATTERY | ¡@ |
| User Replaceable Batteries | 12V / 7.2AH¡Ñ8^ |
| Typical Backup Time (Full / Half load) | 7 / 26 min |
| Recharge Time to 90% | < 4 Hours |
| ADVANCED WARNINGS / DIAGNOSTICS¡@ |
| Front Panel LEDs or LCD | AC mode / Battery mode / Battery Fault / Battery Capacity / Buck Mode / Boost Mode / Load Percentage / Overload |
| Audible Alarms | Battery mode / UPS fault / Overload |
| COMMUNICATIONS INTERFACE | ¡@ |
| Communication Port | RS232 or USB Port* |
| ENVIRONMENTAL | ¡@ |
| Operation Temperature | 0~40¢J / 32~104¢K |
| Storage Temperature | -20~60¢J / -4~140¢K |
| Audible Noise (AC Mode) | < 40dBA |
| PHYSICAL | ¡@ |
Dimensions(Physical / Packing) (L¡ÑW¡ÑH) | 17.7¡Ñ6.7¡Ñ8.5 / 22¡Ñ11.8¡Ñ13.58 (in) 450¡Ñ170¡Ñ215 / 560¡Ñ300¡Ñ345 (mm) |
| Weight (Net / Gross) | 41.9 /46.3 (lbs) 19 / 21 (kg) |
| Battery Box (Net / Gross) (kg) | 25.6 / 27.2 |
| Battery Box Dimensions (Physical / Packing) (L¡ÑW¡ÑH) | 17.52¡Ñ6.69¡Ñ8.46 / 21.65¡Ñ11.81¡Ñ13.58 (in) 450¡Ñ170¡Ñ215 / 560¡Ñ300¡Ñ345 (mm) |
| CONFORMANCE | ¡@ |
| Approvals | UL / cUL; C-Tick, A-Tick; BSMI; CE; GOST-R |
| Specifications are subject to change without notice. |
| ^ Battery unit is included with PS232 and PS3000B. Battery unit needs to be connected to Master unit before connecting any loads and turning on the UPS |
| # RS232 and USB model Provides both RS232 and USB connectivity, but only one connectivity can be used at a time. RS232 model provides only RS232 connectivity, but RS232 can be upgraded to USB connectivity through USP-Serial adapter. |
| * You can purchase RS232 to USB cable.¡@ |
| ** Backup time depends on power consumption of equipment attached and on UPS battery capacity. Numbers here are for reference only. |