An Online UPS is not a further improvement of the standby technology, but a completely different approach to providing the highest level of power supply. A double-conversion refers to converting the incoming AC power into DC power, and inverting it back to AC power. This ensures the newly reproduced power to be of a quality standard set by UPS, to be completely cleared of all imperfections of the power coming from the AC mains. Regardless of what is going on the AC mains side, the UPS output voltage, frequency and signal purity are kept up to the highest standards. The current flow is absolutely uninterruptible, the transfer time is zero. The UPS can work in pair with diesel generator, and can accommodate additional battery cabinets for a longer backup time.

Beside those, the Durable Series UPS offer a set of essential features that make these UPS a flexible power supply control and power saving tool.

By now the Durable Series UPS perfectly serve their purpose in numerous data processing, medical, banking and other mission critical centres around the globe.

Features
* Zero transfer time (online)
* Smart fan speed control
* Saves more power and minimizes noise
* 4 hours recharge time
* Cold start (DC power on)
* EPO port ready: emergency power off switch
* SNMP card slot available
* Hot swappable / replaceable battery: continuous operation even when battery is being replaced
* Extended battery pack (optional)
* RS232 and USB port
* Full version of OPTI-SAFE Xtreme software

Specifications

Model Name

DS1000B

Topology

True On-Line, Double Conversion

On-battery Output Waveform

Sine Wave

Number of Phase

Single Phase (2W+G)

INPUT

 

Maximum Capacity

1000VA / 700W

Nominal Input Voltage

100/110/120Vac or 220/230/240Vac

Input Voltage Regulation

80-144Vac or 160-276Vac

Nominal Input Frequency

50Hz / 60Hz Auto Sensing

Input PFC

0.97@Full load

Input Short Protection

Circuit Breaker

OUTPUT

 

Nominal Output Voltage

100/110/115/120/127Vac or 208/220/230/240Vac (selectable)

Output Voltage Regulation

Rated Voltage +/-2%

Output T.H.D

3% T.H.D at Linear Load

High Efficiency Mode (AC to AC)

92%

Crest Factor

3 : 1

Start on Battery

Yes

Auto Restart

Yes

Number of Outlets

6 Battery backup (US)

4 Battery backup (IEC)

PROTECTION

 

Data Line Surge Protection

RJ11 / RJ45

BATTERY

 

User Replaceable Batteries

36V / 12V7.2Ah × 3

Typical Backup Time (Full / Half load)

6 / 18 min

Recharge Time to 90%

4 Hours

Extended Battery Pack

BP1000

ADVANCED WARNINGS / DIAGNOSTICS

Front Panel LEDs

AC mode / On line / On battery / Bypass / Fault / Overload and 15 UPS Parameters

Audible Alarms

Battery mode / UPS faults / Overload

COMMUNICATION INTERFACE

 

Communication Port

RS232 and USB

SNMP Manageable

Yes

ENVIRONMENTAL

 

Operation Temperature

0~40°C / 32~104°F

Storage Temperature

-20~60°C / -4~140°F

Relative Humidity

0~95% humidity, non-condensing

Audible Noise

 

PHYSICAL

 

Dimensions (Physical / Packing) (inches)

16.5×6×9.4 / 21.5×11×14

(L×W×H) (mm)

420×152×238 / 545×280×355

Weight (Net / Gross)

36.4 / 40.6 (lbs)   16.5 / 18.4 (kg)

Battery Pack (Net / Gross)

21.1 / 22.6 (kg)

Battery Pack Dimensions (Physical / Packing)

16.5×6×9.4 / 21.5×11×14 (inches)

(L×W×H)(mm)

420×152×238 / 545×280×355

CONFORMANCE

 

EMI / RFI Compatibility

CE; UL/ cUL, C-Tick, A-Tick; GOST-R

 